CO2 Fire System
CO2 Fire System

CO2 Fire System

MOQ : 10 Units

CO2 Fire System Specification

  • Usage
  • Fire safety
  • Control Type
  • Automatic / Manual
  • Installation Type
  • Wall Mounted / Floor Standing
  • Working Temperature
  • -20C to +55C
  • Technology
  • Total Flooding, Local Application
  • Voltage
  • 24V DC (actuation)
  • Operating Pressure
  • 45-60 bar
  • Fire Class
  • Class B and C
  • Features
  • Non-Conductive, Residue Free, Fast Discharge, High Efficiency
  • Connectivity Type
  • Electrical / Pneumatic Release Mechanisms
  • Fire Extinguisher Type
  • CO2 (Carbon Dioxide) Flooding System
  • Coverage Area
  • Varies as per System Design, typically up to 200 m2
  • Material
  • Mild steel
  • Mounting Type
  • Floor / Bracket Mounted
  • Shape
  • Cylinder
  • Warranty
  • Yes
  • Product Type
  • CO2 Fire System
  • Coating Type
  • Corrosion Resistant Powder Coating
  • Application
  • Fire protection equipment
  • Max Flow Rate
  • Up to 45 kg/min
  • Diameter
  • 6.8 mm (Discharge Nozzle)
  • Capacity
  • 2.2 kg to 45 kg Cylinders
  • Pressure
  • 60 bar (CO2 Cylinder Charging)
  • System Actuation
  • Solenoid / Manual Pull Station
  • Refillability
  • Rechargeable Cylinders
  • Color
  • Red (Standard)
  • Approval / Certification
  • CE / ISI Certified
  • Maintenance Interval
  • 12 Months
  • Safety Devices
  • Pressure Relief Valve, Locking Pin
  • Nozzle Type
  • 360 Discharge Multi-port
  • Cylinder Material
  • Seamless Steel
  • Storage Condition
  • Indoor
  • Alarm Integration
  • Compatible with Fire Alarm Systems
  • Hose Material
  • High Pressure Rubber Hose
  • Discharge Time
  • Under 60 seconds
 

CO2 Fire System Trade Information

  • Minimum Order Quantity
  • 10 Units
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 5000 Units Per Month
  • Delivery Time
  • 7-10 Days
  • Main Domestic Market
  • All India
 

About CO2 Fire System

A CO2 Fire System is a type of fire protection system designed to extinguish fires by displacing oxygen and cooling the fire area with carbon dioxide (CO2). It is commonly used in areas where valuable equipment or assets need protection, such as computer rooms, control rooms, and electrical substations. CO2 is a colorless, odorless, and non-conductive gas that is highly effective at suppressing fires involving flammable liquids and electrical equipment. CO2 Fire System is a valuable fire protection tool, particularly for high-hazard applications where rapid and effective fire suppression is critical to prevent damage and ensure safety.



Fast and Efficient Fire Suppression

Our CO2 Fire System ensures rapid response against Class B and C fires. With a maximum flow rate of 45 kg/min and discharge times under 60 seconds, it delivers high efficiency and residue-free extinguishing. The system leverages a 360-degree multi-port nozzle for comprehensive area coverage, suitable for spaces up to 200 m2, minimizing fire damage and downtime.


Versatile Installation and Operation

Engineered for both wall-mounted and floor-standing configurations, the CO2 Fire System adapts seamlessly to various environments, from industrial plants to server rooms. The system accepts electrical or pneumatic release mechanisms and supports both automatic and manual actuation, guaranteeing flexibility in emergency scenarios and ease of integration with existing fire protection infrastructure.


Durability and Certified Safety

Constructed from seamless mild steel and coated with corrosion-resistant powder, each cylinder offers enduring strength and protection. The inclusion of pressure relief valves, locking pins, and high-pressure rubber hoses ensures operational safety. All systems are CE and ISI certified, providing assurance of quality and compliance with international fire safety standards.

FAQ's of CO2 Fire System:


Q: How does the CO2 Fire System activate during a fire emergency?

A: The system can be triggered automatically via compatible fire alarm integrations or manually using a solenoid or pull station. This dual actuation capability ensures quick and reliable discharge of CO2 to suppress fires as soon as they are detected.

Q: What types of fires is this CO2 Fire System suitable for?

A: Designed primarily for Class B (flammable liquids and gases) and Class C (electrical) fires, CO2 is non-conductive and leaves no residue, making it ideal for sensitive areas like electrical rooms, control panels, and server facilities.

Q: When should the CO2 System be maintained or refilled?

A: The system is designed with rechargeable cylinders and requires maintenance at least every 12 months. After any discharge or as part of routine checks, cylinders should be inspected and refilled by qualified service professionals to ensure optimal readiness.

Q: Where can the CO2 Fire System be installed?

A: Suitable for indoor environments, installations can be configured as wall-mounted, floor-standing, or bracket-mounted based on your facility's layout and fire protection requirements. Coverage areas typically extend up to 200 m2, adapting to specific design parameters.

Q: What is the process for refilling and maintaining the CO2 cylinders?

A: Refilling involves safely depressurizing, refilling with CO2 to the correct pressure (up to 60 bar), and resealing by certified technicians. Annual inspections cover testing the high-pressure hoses, verifying safety devices (pressure relief valves, locking pins), and checking for corrosion or damage.

Q: What are the key benefits of using a CO2 Fire System?

A: CO2 systems respond swiftly, effectively suppress a wide range of fire types without leaving residue, are non-conductive, and feature high discharge efficiency. Their design also prioritizes safety with integrated relief valves, robust construction, and corrosion-resistant coatings.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Suppression System Category

FN-200 Fire System

FN-200 Fire System

Minimum Order Quantity : 10 Units

Usage : Fire safety

Pressure : 25 Bar to 42 Bar (Cylinder Storage Pressure)

Working Temperature : 30C to +55C

Installation Type : Ceiling/Wall Mounted or Cylinder Cabinet Based

Control Type : Automatic / Manual

Clean Agent Fire Suppression Tube

Clean Agent Fire Suppression Tube

Minimum Order Quantity : 10

Usage : Fire safety

Pressure : 15 Bar (standard operation)

Working Temperature : 20C to +55C

Installation Type : Direct, Onsite panel or enclosure installation

Control Type : Automatic (PreEngineered, NonElectrical)